W24×76 Steel Beam

A W24×76 is a wide flange steel beam 23.9 inches deep with 8.99-inch flanges, weighing 76 pounds per foot. In ASTM A992 steel (Fy = 50 ksi) it has a design bending strength of 750 kip-ft (LRFD) when its compression flange is braced, and a design shear strength of 315 kips.

Weight76 lb/ft
Depth23.9 in
Ix2100 in4
Sx176 in3
Zx200 in3
φMn750 kip-ft

Design a W24×76 beam Opens a 36 ft span in the free beam designer.

bf = 8.99 in d = 23.9 in tw = 0.44 in tf = 0.68 in

W24×76 dimensions

DimensionValue
Depth, d23.9 in
Flange width, bf8.99 in
Flange thickness, tf0.680 in
Web thickness, tw0.440 in
Distance to web toe of fillet, kdes1.18 in
Distance between flange centroids, ho23.22 in
Cross-sectional area, A22.4 in2
Weight76 lb/ft

Dimensions are AISC design values. Detailing dimensions are rounded to the nearest 1/16 in.

W24×76 section properties

PropertyStrong axis (x)Weak axis (y)
Moment of inertia, I2100 in482.5 in4
Elastic section modulus, S176 in318.4 in3
Plastic section modulus, Z200 in328.6 in3
Radius of gyration, r9.69 in1.92 in
Torsion and slendernessValue
Torsional constant, J2.68 in4
Warping constant, Cw11100 in6
Effective radius of gyration, rts2.33 in
Flange slenderness, bf/2tf6.61
Web slenderness, h/tw49.0

W24×76 bending and shear strength

For ASTM A992 steel (Fy = 50 ksi, E = 29,000 ksi) per AISC 360-16. Its flanges and web are compact for bending, so with its compression flange braced it reaches its full plastic moment.

StrengthLRFDASD
Bending, compression flange bracedφMn = 750 kip-ftMn/Ω = 499 kip-ft
ShearφVn = 315 kipsVn/Ω = 210 kips

If the compression flange isn't braced, the beam can buckle sideways before it yields. Up to Lp = 6.8 ft between braces it keeps its full strength; past Lr = 19.5 ft it buckles elastically. With uniform moment between braces (Cb = 1.0):

Unbraced length, LbφMn (LRFD)Mn/Ω (ASD)
Braced750 kip-ft499 kip-ft
5 ft750 kip-ft499 kip-ft
6.8 ft (Lp)750 kip-ft499 kip-ft
10 ft677 kip-ft451 kip-ft
15 ft564 kip-ft375 kip-ft
19.5 ft (Lr)461 kip-ft307 kip-ft
20 ft443 kip-ft295 kip-ft
25 ft310 kip-ft206 kip-ft
30 ft236 kip-ft157 kip-ft
35 ft190 kip-ft126 kip-ft
40 ft159 kip-ft106 kip-ft

A beam with a uniform load between braces has Cb above 1.0 (1.14 for a simple span braced only at its ends), so these values are conservative. The beam designer works out Cb for every segment between braces.

W24×76 load table by span

The largest uniform load a simply supported W24×76 can carry, in kips per foot, with its compression flange braced along its length (by a floor or roof deck, for example). The loads include the beam's own weight of 0.076 kips per foot.

SpanFactored load (LRFD)Allowable load (ASD)Load at span/360Load at span/240
12 ft41.727.752.278.3
14 ft30.620.432.949.3
16 ft23.415.622.033.0
18 ft18.512.315.523.2
20 ft15.09.9811.316.9
22 ft12.48.258.4712.7
24 ft10.46.936.539.79
26 ft8.885.915.137.70
28 ft7.655.094.116.16
30 ft6.674.443.345.01
32 ft5.863.902.754.13
34 ft5.193.452.303.44
36 ft4.633.081.932.90
38 ft4.162.761.642.47
40 ft3.752.501.412.11
42 ft3.402.261.221.83
44 ft3.102.061.061.59
46 ft2.841.890.931.39
48 ft2.601.730.821.22
50 ft2.401.600.721.08
52 ft2.221.480.640.96
54 ft2.061.370.570.86
56 ft1.911.270.510.77
58 ft1.781.190.460.69
60 ft1.671.110.420.63
  • Factored and allowable loads are limited by bending, or by shear where marked *.
  • The deflection columns are the service loads that make the beam sag span/360 or span/240. Compare span/360 with the live load alone and span/240 with dead plus live load, the usual floor limits in IBC Table 1604.3.

Reading the table

At a 36 ft span, a W24×76 carries a factored load of 4.63 kips per foot (LRFD) or an allowable load of 3.08 kips per foot (ASD). A live load of 1.93 kips per foot would deflect it span/360, which is 1.20 in. The beam works if the factored load is under the first number and the live and total loads are under the deflection numbers. For other spans, supports or loads, open it in the beam designer, or follow the steel beam design guide to check one by hand.

W24×76 questions

What does W24×76 mean?

W means a wide flange shape. 24 is its nominal depth in inches (the actual depth is 23.9 in) and 76 is its weight in pounds per foot.

How much does a W24×76 weigh?

76 pounds per foot, so a 20 ft W24×76 weighs about 1,520 pounds.

How far can a W24×76 span?

It depends on the load. Braced along its length, it carries 41.7 kips per foot of factored load at 12 ft and 1.67 kips per foot at 60 ft; the load table has the spans in between. Floor beams are often 36 to 48 ft for this depth (span-to-depth ratios of about 18 to 24), where deflection usually governs.

Is a W24×76 a compact section?

Yes. Its flanges (bf/2tf = 6.61) and web (h/tw = 49.0) are both compact for bending in 50 ksi steel.