W24×117 Steel Beam

A W24×117 is a wide flange steel beam 24.3 inches deep with 12.8-inch flanges, weighing 117 pounds per foot. In ASTM A992 steel (Fy = 50 ksi) it has a design bending strength of 1,226 kip-ft (LRFD) when its compression flange is braced, and a design shear strength of 401 kips.

Weight117 lb/ft
Depth24.3 in
Ix3540 in4
Sx291 in3
Zx327 in3
φMn1,226 kip-ft

Design a W24×117 beam Opens a 36 ft span in the free beam designer.

bf = 12.8 in d = 24.3 in tw = 0.55 in tf = 0.85 in

W24×117 dimensions

DimensionValue
Depth, d24.3 in
Flange width, bf12.8 in
Flange thickness, tf0.850 in
Web thickness, tw0.550 in
Distance to web toe of fillet, kdes1.35 in
Distance between flange centroids, ho23.45 in
Cross-sectional area, A34.4 in2
Weight117 lb/ft

Dimensions are AISC design values. Detailing dimensions are rounded to the nearest 1/16 in.

W24×117 section properties

PropertyStrong axis (x)Weak axis (y)
Moment of inertia, I3540 in4297 in4
Elastic section modulus, S291 in346.5 in3
Plastic section modulus, Z327 in371.4 in3
Radius of gyration, r10.1 in2.94 in
Torsion and slendernessValue
Torsional constant, J6.72 in4
Warping constant, Cw40800 in6
Effective radius of gyration, rts3.46 in
Flange slenderness, bf/2tf7.53
Web slenderness, h/tw39.2

W24×117 bending and shear strength

For ASTM A992 steel (Fy = 50 ksi, E = 29,000 ksi) per AISC 360-16. Its flanges and web are compact for bending, so with its compression flange braced it reaches its full plastic moment.

StrengthLRFDASD
Bending, compression flange bracedφMn = 1,226 kip-ftMn/Ω = 816 kip-ft
ShearφVn = 401 kipsVn/Ω = 267 kips

If the compression flange isn't braced, the beam can buckle sideways before it yields. Up to Lp = 10.4 ft between braces it keeps its full strength; past Lr = 30.4 ft it buckles elastically. With uniform moment between braces (Cb = 1.0):

Unbraced length, LbφMn (LRFD)Mn/Ω (ASD)
Braced1,226 kip-ft816 kip-ft
10 ft1,226 kip-ft816 kip-ft
10.4 ft (Lp)1,226 kip-ft816 kip-ft
20 ft1,005 kip-ft668 kip-ft
30 ft774 kip-ft515 kip-ft
30.4 ft (Lr)764 kip-ft508 kip-ft
40 ft511 kip-ft340 kip-ft
50 ft378 kip-ft251 kip-ft
60 ft300 kip-ft200 kip-ft

A beam with a uniform load between braces has Cb above 1.0 (1.14 for a simple span braced only at its ends), so these values are conservative. The beam designer works out Cb for every segment between braces.

W24×117 load table by span

The largest uniform load a simply supported W24×117 can carry, in kips per foot, with its compression flange braced along its length (by a floor or roof deck, for example). The loads include the beam's own weight of 0.117 kips per foot.

SpanFactored load (LRFD)Allowable load (ASD)Load at span/360Load at span/240
12 ft66.8*44.6*88.0132.0
14 ft50.133.355.483.1
16 ft38.325.537.155.7
18 ft30.320.126.139.1
20 ft24.516.319.028.5
22 ft20.313.514.321.4
24 ft17.011.311.016.5
26 ft14.59.668.6513.0
28 ft12.58.336.9310.4
30 ft10.97.255.638.45
32 ft9.586.374.646.96
34 ft8.495.653.875.80
36 ft7.575.043.264.89
38 ft6.794.522.774.16
40 ft6.134.082.383.56
42 ft5.563.702.053.08
44 ft5.073.371.792.68
46 ft4.643.081.562.34
48 ft4.262.831.382.06
50 ft3.922.611.221.83
52 ft3.632.411.081.62
54 ft3.362.240.971.45
56 ft3.132.080.871.30
58 ft2.921.940.781.17
60 ft2.731.810.701.06
  • Factored and allowable loads are limited by bending, or by shear where marked *.
  • The deflection columns are the service loads that make the beam sag span/360 or span/240. Compare span/360 with the live load alone and span/240 with dead plus live load, the usual floor limits in IBC Table 1604.3.

Reading the table

At a 36 ft span, a W24×117 carries a factored load of 7.57 kips per foot (LRFD) or an allowable load of 5.04 kips per foot (ASD). A live load of 3.26 kips per foot would deflect it span/360, which is 1.20 in. The beam works if the factored load is under the first number and the live and total loads are under the deflection numbers. For other spans, supports or loads, open it in the beam designer, or follow the steel beam design guide to check one by hand.

W24×117 questions

What does W24×117 mean?

W means a wide flange shape. 24 is its nominal depth in inches (the actual depth is 24.3 in) and 117 is its weight in pounds per foot.

How much does a W24×117 weigh?

117 pounds per foot, so a 20 ft W24×117 weighs about 2,340 pounds.

How far can a W24×117 span?

It depends on the load. Braced along its length, it carries 66.8 kips per foot of factored load at 12 ft and 2.73 kips per foot at 60 ft; the load table has the spans in between. Floor beams are often 36 to 49 ft for this depth (span-to-depth ratios of about 18 to 24), where deflection usually governs.

Is a W24×117 a compact section?

Yes. Its flanges (bf/2tf = 7.53) and web (h/tw = 39.2) are both compact for bending in 50 ksi steel.