W18×60 Steel Beam

A W18×60 is a wide flange steel beam 18.2 inches deep with 7.56-inch flanges, weighing 60 pounds per foot. In ASTM A992 steel (Fy = 50 ksi) it has a design bending strength of 461 kip-ft (LRFD) when its compression flange is braced, and a design shear strength of 227 kips.

Weight60 lb/ft
Depth18.2 in
Ix984 in4
Sx108 in3
Zx123 in3
φMn461 kip-ft

Design a W18×60 beam Opens a 27 ft span in the free beam designer.

bf = 7.56 in d = 18.2 in tw = 0.415 in tf = 0.695 in

W18×60 dimensions

DimensionValue
Depth, d18.2 in
Flange width, bf7.56 in
Flange thickness, tf0.695 in
Web thickness, tw0.415 in
Distance to web toe of fillet, kdes1.10 in
Distance between flange centroids, ho17.51 in
Cross-sectional area, A17.6 in2
Weight60 lb/ft

Dimensions are AISC design values. Detailing dimensions are rounded to the nearest 1/16 in.

W18×60 section properties

PropertyStrong axis (x)Weak axis (y)
Moment of inertia, I984 in450.1 in4
Elastic section modulus, S108 in313.3 in3
Plastic section modulus, Z123 in320.6 in3
Radius of gyration, r7.47 in1.68 in
Torsion and slendernessValue
Torsional constant, J2.17 in4
Warping constant, Cw3850 in6
Effective radius of gyration, rts2.02 in
Flange slenderness, bf/2tf5.44
Web slenderness, h/tw38.7

W18×60 bending and shear strength

For ASTM A992 steel (Fy = 50 ksi, E = 29,000 ksi) per AISC 360-16. Its flanges and web are compact for bending, so with its compression flange braced it reaches its full plastic moment.

StrengthLRFDASD
Bending, compression flange bracedφMn = 461 kip-ftMn/Ω = 307 kip-ft
ShearφVn = 227 kipsVn/Ω = 151 kips

If the compression flange isn't braced, the beam can buckle sideways before it yields. Up to Lp = 5.9 ft between braces it keeps its full strength; past Lr = 18.2 ft it buckles elastically. With uniform moment between braces (Cb = 1.0):

Unbraced length, LbφMn (LRFD)Mn/Ω (ASD)
Braced461 kip-ft307 kip-ft
5 ft461 kip-ft307 kip-ft
5.9 ft (Lp)461 kip-ft307 kip-ft
10 ft402 kip-ft268 kip-ft
15 ft330 kip-ft219 kip-ft
18.2 ft (Lr)284 kip-ft189 kip-ft
20 ft247 kip-ft164 kip-ft
25 ft181 kip-ft120 kip-ft
30 ft143 kip-ft95.0 kip-ft
35 ft118 kip-ft78.6 kip-ft

A beam with a uniform load between braces has Cb above 1.0 (1.14 for a simple span braced only at its ends), so these values are conservative. The beam designer works out Cb for every segment between braces.

W18×60 load table by span

The largest uniform load a simply supported W18×60 can carry, in kips per foot, with its compression flange braced along its length (by a floor or roof deck, for example). The loads include the beam's own weight of 0.060 kips per foot.

SpanFactored load (LRFD)Allowable load (ASD)Load at span/360Load at span/240
9 ft45.630.358.087.0
11 ft30.520.331.847.6
13 ft21.814.519.228.9
15 ft16.410.912.518.8
17 ft12.88.508.6012.9
19 ft10.26.806.169.25
21 ft8.375.574.566.85
23 ft6.984.643.475.21
25 ft5.903.932.714.06
27 ft5.063.372.153.22
29 ft4.392.921.732.60
31 ft3.842.551.422.13
33 ft3.392.251.181.76
35 ft3.012.000.991.48
37 ft2.701.790.831.25
39 ft2.431.610.711.07
41 ft2.201.460.610.92
43 ft2.001.330.530.80
45 ft1.821.210.460.70
  • Factored and allowable loads are limited by bending, or by shear where marked *.
  • The deflection columns are the service loads that make the beam sag span/360 or span/240. Compare span/360 with the live load alone and span/240 with dead plus live load, the usual floor limits in IBC Table 1604.3.

Reading the table

At a 27 ft span, a W18×60 carries a factored load of 5.06 kips per foot (LRFD) or an allowable load of 3.37 kips per foot (ASD). A live load of 2.15 kips per foot would deflect it span/360, which is 0.90 in. The beam works if the factored load is under the first number and the live and total loads are under the deflection numbers. For other spans, supports or loads, open it in the beam designer, or follow the steel beam design guide to check one by hand.

W18×60 questions

What does W18×60 mean?

W means a wide flange shape. 18 is its nominal depth in inches (the actual depth is 18.2 in) and 60 is its weight in pounds per foot.

How much does a W18×60 weigh?

60 pounds per foot, so a 20 ft W18×60 weighs about 1,200 pounds.

How far can a W18×60 span?

It depends on the load. Braced along its length, it carries 45.6 kips per foot of factored load at 9 ft and 1.82 kips per foot at 45 ft; the load table has the spans in between. Floor beams are often 27 to 36 ft for this depth (span-to-depth ratios of about 18 to 24), where deflection usually governs.

Is a W18×60 a compact section?

Yes. Its flanges (bf/2tf = 5.44) and web (h/tw = 38.7) are both compact for bending in 50 ksi steel.