W18×40 Steel Beam

A W18×40 is a wide flange steel beam 17.9 inches deep with 6.02-inch flanges, weighing 40 pounds per foot. In ASTM A992 steel (Fy = 50 ksi) it has a design bending strength of 294 kip-ft (LRFD) when its compression flange is braced, and a design shear strength of 169 kips.

Weight40 lb/ft
Depth17.9 in
Ix612 in4
Sx68.4 in3
Zx78.4 in3
φMn294 kip-ft

Design a W18×40 beam Opens a 27 ft span in the free beam designer.

bf = 6.02 in d = 17.9 in tw = 0.315 in tf = 0.525 in

W18×40 dimensions

DimensionValue
Depth, d17.9 in
Flange width, bf6.02 in
Flange thickness, tf0.525 in
Web thickness, tw0.315 in
Distance to web toe of fillet, kdes0.927 in
Distance between flange centroids, ho17.38 in
Cross-sectional area, A11.8 in2
Weight40 lb/ft

Dimensions are AISC design values. Detailing dimensions are rounded to the nearest 1/16 in.

W18×40 section properties

PropertyStrong axis (x)Weak axis (y)
Moment of inertia, I612 in419.1 in4
Elastic section modulus, S68.4 in36.35 in3
Plastic section modulus, Z78.4 in310.0 in3
Radius of gyration, r7.21 in1.27 in
Torsion and slendernessValue
Torsional constant, J0.810 in4
Warping constant, Cw1440 in6
Effective radius of gyration, rts1.56 in
Flange slenderness, bf/2tf5.73
Web slenderness, h/tw50.9

W18×40 bending and shear strength

For ASTM A992 steel (Fy = 50 ksi, E = 29,000 ksi) per AISC 360-16. Its flanges and web are compact for bending, so with its compression flange braced it reaches its full plastic moment.

StrengthLRFDASD
Bending, compression flange bracedφMn = 294 kip-ftMn/Ω = 196 kip-ft
ShearφVn = 169 kipsVn/Ω = 113 kips

If the compression flange isn't braced, the beam can buckle sideways before it yields. Up to Lp = 4.5 ft between braces it keeps its full strength; past Lr = 13.1 ft it buckles elastically. With uniform moment between braces (Cb = 1.0):

Unbraced length, LbφMn (LRFD)Mn/Ω (ASD)
Braced294 kip-ft196 kip-ft
2 ft294 kip-ft196 kip-ft
4 ft294 kip-ft196 kip-ft
4.5 ft (Lp)294 kip-ft196 kip-ft
6 ft274 kip-ft182 kip-ft
8 ft247 kip-ft164 kip-ft
10 ft221 kip-ft147 kip-ft
12 ft194 kip-ft129 kip-ft
13.1 ft (Lr)180 kip-ft119 kip-ft
14 ft160 kip-ft107 kip-ft
16 ft130 kip-ft86.4 kip-ft
18 ft109 kip-ft72.2 kip-ft
20 ft93.0 kip-ft61.9 kip-ft
22 ft81.2 kip-ft54.0 kip-ft

A beam with a uniform load between braces has Cb above 1.0 (1.14 for a simple span braced only at its ends), so these values are conservative. The beam designer works out Cb for every segment between braces.

W18×40 load table by span

The largest uniform load a simply supported W18×40 can carry, in kips per foot, with its compression flange braced along its length (by a floor or roof deck, for example). The loads include the beam's own weight of 0.040 kips per foot.

SpanFactored load (LRFD)Allowable load (ASD)Load at span/360Load at span/240
9 ft29.019.336.154.1
11 ft19.412.919.829.6
13 ft13.99.2612.018.0
15 ft10.56.957.7911.7
17 ft8.145.415.358.03
19 ft6.524.333.835.75
21 ft5.333.552.844.26
23 ft4.452.962.163.24
25 ft3.762.501.682.52
27 ft3.232.151.342.00
29 ft2.801.861.081.62
31 ft2.451.630.881.32
33 ft2.161.440.731.10
35 ft1.921.280.610.92
37 ft1.721.140.520.78
39 ft1.551.030.440.66
41 ft1.400.930.380.57
43 ft1.270.850.330.50
45 ft1.160.770.290.43
  • Factored and allowable loads are limited by bending, or by shear where marked *.
  • The deflection columns are the service loads that make the beam sag span/360 or span/240. Compare span/360 with the live load alone and span/240 with dead plus live load, the usual floor limits in IBC Table 1604.3.

Reading the table

At a 27 ft span, a W18×40 carries a factored load of 3.23 kips per foot (LRFD) or an allowable load of 2.15 kips per foot (ASD). A live load of 1.34 kips per foot would deflect it span/360, which is 0.90 in. The beam works if the factored load is under the first number and the live and total loads are under the deflection numbers. For other spans, supports or loads, open it in the beam designer, or follow the steel beam design guide to check one by hand.

W18×40 questions

What does W18×40 mean?

W means a wide flange shape. 18 is its nominal depth in inches (the actual depth is 17.9 in) and 40 is its weight in pounds per foot.

How much does a W18×40 weigh?

40 pounds per foot, so a 20 ft W18×40 weighs about 800 pounds.

How far can a W18×40 span?

It depends on the load. Braced along its length, it carries 29.0 kips per foot of factored load at 9 ft and 1.16 kips per foot at 45 ft; the load table has the spans in between. Floor beams are often 27 to 36 ft for this depth (span-to-depth ratios of about 18 to 24), where deflection usually governs.

Is a W18×40 a compact section?

Yes. Its flanges (bf/2tf = 5.73) and web (h/tw = 50.9) are both compact for bending in 50 ksi steel.