W14×82 Steel Beam

A W14×82 is a wide flange steel beam 14.3 inches deep with 10.1-inch flanges, weighing 82 pounds per foot. In ASTM A992 steel (Fy = 50 ksi) it has a design bending strength of 521 kip-ft (LRFD) when its compression flange is braced, and a design shear strength of 219 kips.

Weight82 lb/ft
Depth14.3 in
Ix881 in4
Sx123 in3
Zx139 in3
φMn521 kip-ft

Design a W14×82 beam Opens a 21 ft span in the free beam designer.

bf = 10.1 in d = 14.3 in tw = 0.51 in tf = 0.855 in

W14×82 dimensions

DimensionValue
Depth, d14.3 in
Flange width, bf10.1 in
Flange thickness, tf0.855 in
Web thickness, tw0.510 in
Distance to web toe of fillet, kdes1.45 in
Distance between flange centroids, ho13.45 in
Cross-sectional area, A24.0 in2
Weight82 lb/ft

Dimensions are AISC design values. Detailing dimensions are rounded to the nearest 1/16 in.

W14×82 section properties

PropertyStrong axis (x)Weak axis (y)
Moment of inertia, I881 in4148 in4
Elastic section modulus, S123 in329.3 in3
Plastic section modulus, Z139 in344.8 in3
Radius of gyration, r6.05 in2.48 in
Torsion and slendernessValue
Torsional constant, J5.07 in4
Warping constant, Cw6710 in6
Effective radius of gyration, rts2.85 in
Flange slenderness, bf/2tf5.92
Web slenderness, h/tw22.4

W14×82 bending and shear strength

For ASTM A992 steel (Fy = 50 ksi, E = 29,000 ksi) per AISC 360-16. Its flanges and web are compact for bending, so with its compression flange braced it reaches its full plastic moment.

StrengthLRFDASD
Bending, compression flange bracedφMn = 521 kip-ftMn/Ω = 347 kip-ft
ShearφVn = 219 kipsVn/Ω = 146 kips

If the compression flange isn't braced, the beam can buckle sideways before it yields. Up to Lp = 8.8 ft between braces it keeps its full strength; past Lr = 33.1 ft it buckles elastically. With uniform moment between braces (Cb = 1.0):

Unbraced length, LbφMn (LRFD)Mn/Ω (ASD)
Braced521 kip-ft347 kip-ft
8.8 ft (Lp)521 kip-ft347 kip-ft
10 ft511 kip-ft340 kip-ft
20 ft430 kip-ft286 kip-ft
30 ft348 kip-ft232 kip-ft
33.1 ft (Lr)323 kip-ft215 kip-ft
40 ft259 kip-ft173 kip-ft
50 ft203 kip-ft135 kip-ft
60 ft167 kip-ft111 kip-ft
70 ft142 kip-ft94.2 kip-ft

A beam with a uniform load between braces has Cb above 1.0 (1.14 for a simple span braced only at its ends), so these values are conservative. The beam designer works out Cb for every segment between braces.

W14×82 load table by span

The largest uniform load a simply supported W14×82 can carry, in kips per foot, with its compression flange braced along its length (by a floor or roof deck, for example). The loads include the beam's own weight of 0.082 kips per foot.

SpanFactored load (LRFD)Allowable load (ASD)Load at span/360Load at span/240
7 ft62.5*41.7*110.4165.5
9 ft48.6*32.4*51.977.9
11 ft34.522.928.442.7
13 ft24.716.417.225.8
15 ft18.512.311.216.8
17 ft14.49.607.7011.6
19 ft11.67.695.528.28
21 ft9.466.294.096.13
23 ft7.885.243.114.67
25 ft6.674.442.423.63
27 ft5.723.811.922.88
29 ft4.963.301.552.33
31 ft4.342.891.271.91
33 ft3.832.551.051.58
35 ft3.402.260.881.32
  • Factored and allowable loads are limited by bending, or by shear where marked *.
  • The deflection columns are the service loads that make the beam sag span/360 or span/240. Compare span/360 with the live load alone and span/240 with dead plus live load, the usual floor limits in IBC Table 1604.3.

Reading the table

At a 21 ft span, a W14×82 carries a factored load of 9.46 kips per foot (LRFD) or an allowable load of 6.29 kips per foot (ASD). A live load of 4.09 kips per foot would deflect it span/360, which is 0.70 in. The beam works if the factored load is under the first number and the live and total loads are under the deflection numbers. For other spans, supports or loads, open it in the beam designer, or follow the steel beam design guide to check one by hand.

W14×82 questions

What does W14×82 mean?

W means a wide flange shape. 14 is its nominal depth in inches (the actual depth is 14.3 in) and 82 is its weight in pounds per foot.

How much does a W14×82 weigh?

82 pounds per foot, so a 20 ft W14×82 weighs about 1,640 pounds.

How far can a W14×82 span?

It depends on the load. Braced along its length, it carries 62.5 kips per foot of factored load at 7 ft and 3.40 kips per foot at 35 ft; the load table has the spans in between. Floor beams are often 21 to 29 ft for this depth (span-to-depth ratios of about 18 to 24), where deflection usually governs.

Is a W14×82 a compact section?

Yes. Its flanges (bf/2tf = 5.92) and web (h/tw = 22.4) are both compact for bending in 50 ksi steel.