Steel columns to AISC 360-22, wood columns to NDS 2024, reinforced concrete columns to ACI 318-19 and cold-formed steel studs to AISI S100-16, under axial load and bending.

Member

AISI S100-16 (2020). Studs bend about their strong axis: enter wind on a wall as the lateral load w, in pounds per foot of height. The weak axis braces (bridging or sheathing) also stop the stud twisting.

Mx bends it across h.

Corners included.

Corners included.

To the ties; at least 1-1/2 in.

60,000 for Grade 60.

Height and supports

0 if it's braced only at the ends.

Loads

Service loads on the column top, by type. Compression is positive; enter uplift as negative. Wind and earthquake are strength-level loads; the wind load calculator gives wind pressures.

Load combinations from NBCC 2020 Table 4.1.3.2-A, for CSA S16 and CSA O86. NBCC counts roof live load as L and rain as S, so Lr takes the L factor and R the S factor.

Use the edition your snow load comes from. ASCE 7-22 maps snow at strength level and takes 1.0S where snow leads in LRFD (0.7S in ASD); 7-16 takes 1.6S (1.0S).

P (kips)Mx (kip-ft)My (kip-ft)w (plf)

Bends it about x.

Bends it about y.

Results

Drag to turn, scroll or pinch to zoom.

Design the footing under it · Worked steel examples

How the Column Designer Works

The column designer checks one column at a time: a steel W shape, square, rectangular or round Hollow Structural Section (HSS), or pipe to AISC 360-22, or a wood post, glulam, Laminated Veneer Lumber (LVL) or Parallel Strand Lumber (PSL) column to the 2024 National Design Specification for Wood Construction (NDS), or a tied reinforced concrete column to ACI 318-19. Enter the loads at the top of the column by type (dead, live, roof, snow, rain, wind and earthquake) and it builds every ASCE 7-22 or 7-16 load combination, checks each one, and shows the one that governs.

Steel columns (AISC 360-22)

  • Compression (Chapter E): flexural buckling about each axis from the effective length KL/r, with the effective width method of section E7 for slender walls and flanges.
  • Bending (Chapter F): yielding and lateral-torsional buckling of W shapes about the strong axis, using the weak axis brace spacing as the unbraced length, plus local buckling of HSS walls and flanges.
  • Shear (Chapter G) in both directions.
  • Axial load and bending together (Chapter H, equations H1-1a and H1-1b), with the moments amplified for the extra bending caused by the axial load (the B1 factor of Appendix 8).
  • Both Load and Resistance Factor Design (LRFD) and Allowable Strength Design (ASD).

Steel columns (CSA S16-19)

  • Pick CSA S16-19 as the design method for Canadian projects. Loads are combined by NBCC 2020 Table 4.1.3.2-A and entered in kN, kN·m and metres, and shapes are listed by their metric names, such as W310x39.
  • Compression (clause 13.3) with n = 1.34, or 2.24 for Class H HSS, including torsional buckling of W shapes.
  • Bending (13.5 and 13.6) by section class, with lateral-torsional buckling over the weak axis brace spacing, and shear (13.4).
  • Axial load and bending (13.8 and 13.9): cross-sectional, overall member and lateral-torsional buckling strength, with moments amplified by U1.
  • 350W and 300W steel to CSA G40.21. Sections with Class 4 elements beyond what these checks cover are flagged to check by hand.

Wood columns (NDS 2024)

  • Compression with the column stability factor CP (section 3.7), from the slenderness le/d about each axis.
  • Bending with the beam stability factor CL and, for glulam, the volume factor CV.
  • Combined bending and compression (section 3.9.2) and shear (section 3.4.2).
  • The load duration factor CD for each combination, and wet service factors for posts outdoors.
  • Slenderness le/d is limited to 50.

Wood columns (CSA O86-19)

  • Pick CSA O86-19 as the wood design standard for Canadian projects. Loads are combined by NBCC 2020 and entered in kN, kN·m and metres.
  • Sawn posts in 89 mm (4x4 and 4x6) D.Fir-L, Hem-Fir, S-P-F and Northern lumber, Select Structural or No.1/No.2, and glulam in Canadian sizes, 24f-E D.Fir-L or 20f-E Spruce-Pine (Pro). Dry service only.
  • Compression with the slenderness factor KC and size factor KZc about each axis (clause 6.5.6 for sawn lumber, 7.5.8 for glulam), and Cc limited to 50.
  • Bending with the lateral stability factor KL and the size factor, shear, and axial load and bending about both axes (6.5.10), or tension with bending under uplift.
  • The load duration factor KD for each combination: 1.15 with wind or earthquake, 0.65 for dead load alone, and 1.0 otherwise, reduced when the dead load is larger than the other loads (5.3.2.3).

Cold-formed steel studs (AISI S100-16, Pro)

  • Steel Stud Manufacturers Association (SSMA) studs and tracks in 33 or 50 ksi steel, with or without web punchouts, by ASD or LRFD. Enter wind on a wall as a lateral load along the height, in pounds per foot.
  • Compression (Chapter E): flexural buckling about the weak axis between braces and flexural-torsional buckling, local buckling by the effective width method with the punchout, and distortional buckling of the lipped flanges.
  • Bending about the strong axis (Chapter F), shear (Chapter G) and axial load and bending together (H1.2), with the moment amplified by B1; uplift is checked for tension and bending (H1.1).

Reinforced concrete columns (ACI 318-19, Pro)

  • Tied rectangular columns with bars evenly spaced around the perimeter, by the number along each face.
  • Axial load and bending by strain compatibility (section 22.2), with bending about both axes taken together: the neutral axis is turned until the moment strength points the same way as the load's. The strength reduction factor φ comes from the strain in the extreme tension bar (Table 21.2.2), and axial load is capped at 0.80φPo (22.4.2.1).
  • Slenderness (6.2.5): moments of slender columns are magnified for braced columns (6.6.4.5), with the minimum moment of 6.6.4.5.4, or as a sway column for a flagpole (6.6.4.6), and second-order moments are limited to 1.4 times first-order (6.2.6).
  • Shear (22.5) from the change in moment up the height, with the ties as shear reinforcement.
  • The steel limits: 1% to 8% of the area (10.6.1.1), clear space between bars (25.2.3), and tie size and spacing (25.7.2).
  • Strength (LRFD) load combinations from ASCE 7. Bar splices, anchorage and cross-tie layout aren't checked.

End conditions

The effective length factor K comes from how the ends are held, using the recommended values from the AISC commentary:

  • Pinned top and bottom: K = 1.0
  • Fixed base, pinned top: K = 0.8
  • Fixed top and bottom: K = 0.65
  • Fixed base, free top (a flagpole): K = 2.1. The top can sway, so the designer warns that a frame analysis with second-order (P-Δ) effects may be needed.

Bracing against weak axis buckling splits the height into shorter pieces, each taken as pinned.

Example: a steel column

A W8x31 in A992 steel (Fy = 50 ksi), 12 ft tall and pinned at both ends, carries 20 kips of dead load and 30 kips of live load. With LRFD, 1.2D + 1.6L governs: Pu = 1.2(20) + 1.6(30) = 72 kips.

  1. Weak axis slenderness: KL/ry = 1.0 × 144 in / 2.02 in = 71.3.
  2. Elastic buckling stress: Fe = π²E / (KL/r)² = π² × 29,000 / 71.3² = 56.3 ksi.
  3. Fy/Fe = 0.89, under 2.25, so Fcr = 0.6580.89 × 50 = 34.5 ksi (equation E3-2).
  4. Pn = FcrAg = 34.5 × 9.12 = 314 kips, and φPn = 0.9 × 314 = 283 kips.
  5. 72 / 283 = 0.25, so the column passes with plenty of room, and a lighter shape is worth trying.

Example: a wood post

A 6x6 Douglas Fir-Larch No. 2 post indoors, 10 ft tall and pinned at both ends, carries 4 kips dead and 8 kips live. D + L governs at 12 kips, with CD = 1.0.

  1. Actual stress: fc = 12,000 lb / 30.25 in² = 397 psi.
  2. Slenderness: le/d = 120 / 5.5 = 21.8, under the limit of 50.
  3. With Fc = 700 psi and Emin = 470,000 psi, the column stability factor is CP = 0.740.
  4. Allowable stress: Fc' = 700 × 0.740 = 518 psi.
  5. 397 / 518 = 0.77, so the post passes.

What it doesn't check

  • Connections, base plates and anchor bolts. The anchor bolt designer covers the anchors.
  • Tension in wood columns under uplift. The designer flags it when a combination pulls on the column.
  • The frame the column is part of. For a column in a moment frame, get the forces from a frame analysis such as the frame designer.
  • Fire, corrosion and decay.

The results are a design aid. Have a licensed engineer check a design before it's built.

Frequently asked questions

How much load can a steel column carry?

It depends mostly on the shape and its height. Buckling about the weak axis usually governs, so a taller column carries much less. A 12 ft W8x31 in A992 steel carries 283 kips with LRFD. The steel column design examples work through more cases.

How much load can a 6x6 post carry?

A 10 ft Douglas Fir-Larch No. 2 6x6 indoors carries about 15,700 lb of dead plus live load (518 psi × 30.25 in²). A taller post carries less: its stability factor drops as le/d grows.

What K factor should I use?

Use K = 1.0 for a column pinned at both ends, which suits most building columns with simple beam connections and braced frames. Use 2.1 for a column fixed at the base and free at the top.

Is the column designer free?

Yes. Steel columns and sawn wood posts are free without an account. Pro adds glulam, LVL, PSL and reinforced concrete columns, saved columns and PDF reports.

Folder PDF