# Steel Column Design Examples, Worked Step by Step (AISC 360-22)

Source: https://webstructural.com/steel-column-design-examples.html

> Steel column design examples worked step by step to AISC 360-22: a W14x132 column in compression, W18x50 bending strength and bracing, and W14x90 flange local buckling, each checked against the AISC manual.

Three steel checks from the AISC *Steel Construction Manual*, worked by hand to the AISC 360-22 specification: a column in compression, a wide flange beam's bending strength as its bracing changes, and a shape whose flanges are too thin to reach full plastic strength.

Every number on this page comes from the code behind the free [column designer](https://webstructural.com/column-designer.html), so you can follow each step and see it land on the value in the manual. All three shapes are ASTM A992 steel, F_y = 50 ksi and E = 29,000 ksi.

The AISC values and the column designer’s, side by side

| Example | AISC | Here |
| --- | --- | --- |
| 1. W14×132 at 30 ft, &phi;P_n | 893 kips | 893 kips |
| 1. W14×132 at 30 ft, P_n/&Omega; | 594 kips | 594 kips |
| 2. W18×50, &phi;M_p | 379 kip-ft | 379 kip-ft |
| 2. W18×50, L_p | 5.83 ft | 5.83 ft |
| 2. W18×50, L_r | 16.9 ft | 16.96 ft |
| 3. W14×90, &phi;M_n | 574 kip-ft | 574 kip-ft |

## Example 1: a W14×132 column, 30 ft tall

This is AISC Design Example E.1A. A W14×132 column is pinned at the top and bottom and braced only at its ends, so it can buckle over the full 30 ft about either axis (K = 1.0). It carries a dead load of 140 kips and a live load of 420 kips.

### Loads

LRFD (load and resistance factor design) and ASD (allowable strength design) each combine the loads their own way:

LRFD: P_u = 1.2D + 1.6L = 1.2(140) + 1.6(420) = **840 kips**ASCE 7-16 2.3.1

ASD: P_a = D + L = 140 + 420 = **560 kips**ASCE 7-16 2.4.1

### Are the flanges and web thick enough?

If a flange or the web is thin for its width, it wrinkles before the column buckles as a whole, and section E7 cuts the area that counts. Compare each width-to-thickness ratio with its limit from Table B4.1a:

Flange: b_f/2t_f = 7.15 < 0.56&radic;(E/F_y) = 13.5Table B4.1a

Web: h/t_w = 17.7 < 1.49&radic;(E/F_y) = 35.9Table B4.1a

Both pass, so the full area A = 38.8 in^2 works.

### Which axis buckles?

A column buckles about the axis with the larger slenderness, L_c/r. With the same 30 ft (360 in) length both ways, that's the weak axis, the one with the smaller radius of gyration:

Strong axis: L_cx/r_x = 360 / 6.28 = 57.3

Weak axis: L_cy/r_y = 360 / 3.76 = **95.7** (governs)

Under 200, so the column isn't too slenderE2 user note

### Buckling stress

F_e = &pi;^2E / (L_c/r)^2 = &pi;^2(29,000) / 95.7^2 = 31.2 ksiE3-4

F_y/F_e = 50 / 31.2 = 1.60 &le; 2.25, so inelastic bucklingE3-2

F_cr = 0.658^(F_y/F_e) F_y = 0.658^(1.60)(50) = 25.6 ksiE3-2

A W shape can also twist instead of bending sideways. Section E4 gives the twisting buckling stress; for a stocky shape like this one it's far higher, so it doesn't govern:

F_e (twisting) = [&pi;^2EC_w/L_cz^2 + GJ] / (I_x + I_y) = 93.4 ksi > 31.2 ksiE4-2

### Strength

P_n = F_crA_g = 25.58(38.8) = 992 kipsE3-1

LRFD: &phi;_cP_n = 0.90(992) = **893 kips** > 840 kips, OKE1

ASD: P_n/&Omega;_c = 992 / 1.67 = **594 kips** > 560 kips, OKE1

These match the manual's 893 kips and 594 kips, which are also the values in its column load table (Table 4-1a) for a W14×132 at 30 ft. The column uses 94% of its strength under LRFD.

[Open this column in the column designer](https://webstructural.com/column-designer.html?D=140&L=420&height=30&shape=W14X132)

## Example 2: how bracing changes a W18×50's bending strength

A wide flange bent about its strong axis can fail two ways: it yields across the whole section, or its compression flange buckles sideways and twists the beam (lateral-torsional buckling). Which one happens depends on L_b, the length between the points that stop the compression flange moving sideways. The column designer runs this check for every W shape column with a moment about its strong axis.

### Fully braced: the plastic moment

M_p = F_yZ_x = 50(101) = 5,050 kip-in = 420.8 kip-ftF2-1

&phi;_bM_p = 0.90(420.8) = **379 kip-ft**F1

The flanges (b_f/2t_f = 6.57) are under the compact limit of 9.15, so they don't buckle first.

### The two bracing limits

Up to L_p the beam reaches its full plastic moment. Past L_r it buckles elastically. Between them the strength drops along a straight line.

L_p = 1.76r_y&radic;(E/F_y) = 1.76(1.65)(24.1) = 69.9 in = **5.83 ft**F2-5

L_r = 1.95r_ts(E/0.7F_y)&radic;[Jc/S_xh_o + &radic;((Jc/S_xh_o)^2 + 6.76(0.7F_y/E)^2)] = 203.5 in = **16.96 ft**F2-6

with r_ts = 1.98 in, J = 1.24 in^4, c = 1, h_o = 17.43 inF2-7

### Braced every 11.67 ft

Design Example F.1-2A takes this beam on a 35 ft span, braced at its ends and third points, so L_b = 11.67 ft (140 in), between L_p and L_r:

M_n = C_b[M_p − (M_p − 0.7F_yS_x)(L_b − L_p)/(L_r − L_p)]F2-2

= 1.0[5,050 − (5,050 − 3,112)(140 − 69.9)/(203.5 − 69.9)] = 4,033 kip-in

&phi;_bM_n = 0.90(4,033) / 12 = **302 kip-ft**F1

Bracing at 11.67 ft instead of every 5.83 ft costs the beam 20% of its strength. Each extra foot of unbraced length takes &phi;BF = 0.90(5,050 − 3,112) / 133.5 = 13.1 kip-ft off, the slope of the straight line.

C_b raises the strength when the moment isn't constant along the unbraced length. The design example works out C_b for its middle segment; the column designer takes C_b = 1.0, which is the lowest it can be and always safe.

## Example 3: a W14×90 with noncompact flanges

Most wide flange shapes have flanges thick enough to reach the plastic moment. A few of the wide W14 column shapes don't: their flanges are so wide for their thickness that they buckle locally a little before the whole section yields. The manual marks these shapes in its beam tables, and the W14×90 is one of them.

&lambda; = b_f/2t_f = 14.5 / 2(0.71) = 10.2Table B4.1b

&lambda;_p = 0.38&radic;(E/F_y) = 9.15Table B4.1b

&lambda;_r = 1.0&radic;(E/F_y) = 24.08Table B4.1b

9.15 < 10.2 < 24.08, so the flanges are noncompact

The strength drops along a straight line between M_p at &lambda;_p and 0.7F_yS_x at &lambda;_r:

M_p = F_yZ_x = 50(157) = 7,850 kip-inF2-1

M_n = M_p − (M_p − 0.7F_yS_x)(&lambda; − &lambda;_p)/(&lambda;_r − &lambda;_p)F3-1

= 7,850 − (7,850 − 5,005)(10.2 − 9.15)/(24.08 − 9.15) = 7,650 kip-in

&phi;_bM_n = 0.90(7,650) / 12 = **574 kip-ft**F1

That's the 574 kip-ft in Table 3-2, 2.5% under the plastic moment. A program that skips the flange check would report 589 kip-ft and overstate the strength. For weak axis bending, section F6 makes the same flange check.

## Putting them together

A real column usually carries load and bending at once. The column designer works out the compression strength (example 1) and the bending strength about each axis (examples 2 and 3), increases the moments for the extra bending the axial load causes as the column bows (the B_1 factor in Appendix 8), and adds them up with the interaction equations in section H1:

P_r/P_c &ge; 0.2: P_r/P_c + 8/9 (M_rx/M_cx + M_ry/M_cy) &le; 1.0H1-1a

P_r/P_c < 0.2: P_r/2P_c + (M_rx/M_cx + M_ry/M_cy) &le; 1.0H1-1b

It also checks shear, and runs every ASCE 7-16 load combination. Try a column of your own in the free [column designer](https://webstructural.com/column-designer.html); the worked calculations for the combination that governs are under its results.

## Related

- [Column designer](https://webstructural.com/column-designer.html): steel and wood columns under load and bending
- [How to design a steel beam](https://webstructural.com/steel-beam-how-to.html): bending, bracing, shear and deflection
- [Steel beam sizes](https://webstructural.com/steel-beam-sizes.html): W-shape dimensions and properties
- [Load cases and load combinations](https://webstructural.com/load-cases-and-load-combinations.html)