# Beam Deflection Example: Simply Supported Steel Beam, L/360 Check

Source: https://webstructural.com/beam-deflection-example.html

> Worked beam deflection example: a 20 ft simply supported W12x26 under a uniform load and a point load, checked against L/360, then resized to a W16x26 that passes. Formulas and code limits included.

A beam can be strong enough and still sag too much: floors bounce, ceilings crack and doors stick. So beams are also checked against a deflection limit, usually a fraction of the span such as L/360. This example works out the deflection of a simply supported steel beam by hand, checks it, and picks a beam that passes.

## The formulas

For a simply supported beam of span L, stiffness E and moment of inertia I, the largest deflection is at midspan:

- Uniform load w along the span: Δ = 5wL⁴ / (384EI)
- Point load P at midspan: Δ = PL³ / (48EI)

Deflection is linear in the load, so when both act, add them (superposition). Use consistent units: here kips and inches, with E = 29,000 ksi for steel.

For cantilevers, fixed ends and other loads, see the [beam deflection formulas](https://webstructural.com/beam-deflection-formulas.html).

## The problem

A W12x26 steel beam spans 20 ft between simple supports and carries, as live load:

- a uniform load of 1.0 kip/ft, and
- a 6 kip point load at midspan, from a post above.

The building code limit for live load deflection of a floor beam is L/360 (International Building Code Table 1604.3). Does the beam pass?

Values: L = 20 ft = 240 in, w = 1.0 kip/ft = 0.0833 kip/in, I_x = 204 in⁴ for a W12x26 (see the [moment of inertia example](https://webstructural.com/moment-of-inertia-of-an-i-beam.html) for where that comes from).

## Step by step

### Step 1: deflection from the uniform load

Δ_w = 5 × 0.0833 × 240⁴ / (384 × 29,000 × 204) = 0.61 in

### Step 2: deflection from the point load

Δ_P = 6 × 240³ / (48 × 29,000 × 204) = 0.29 in

### Step 3: total and limit

Δ = 0.61 + 0.29 = 0.90 in against L/360 = 240 / 360 = 0.67 in

0.90 in is more than 0.67 in, so the W12x26 fails the deflection check. It deflects L/266.

### Step 4: the moment of inertia needed

Deflection is inversely proportional to I, so the beam needs

I_required = 204 × 0.90 / 0.667 = 276 in⁴

The lightest W shape with I_x of at least 276 in⁴ is a [W16x26](https://webstructural.com/w16x26-beam.html) at 301 in⁴. It deflects 0.90 × 204 / 301 = 0.61 in, under 0.67 in, so it passes, and weighs the same 26 lb/ft as the W12x26. A deeper beam is stiffer for the same steel, because the flanges sit farther from the middle.

Deflection is only one check: the beam also has to be strong enough in bending and shear. The [steel beam design tutorial](https://webstructural.com/steel-beam-how-to.html) goes through those.

## Common deflection limits

| Member | Live load | Total load |
| --- | --- | --- |
| Floor beams and joists | L/360 | L/240 |
| Roof members supporting a plaster ceiling | L/360 | L/240 |
| Roof members supporting a non-plaster ceiling | L/240 | L/180 |
| Roof members with no ceiling | L/180 | L/120 |

From IBC Table 1604.3. Roof rows use roof live, snow or wind load in the "Live load" column. Check the code adopted where you build.

## Check it with the calculators

- The [beam deflection formulas](https://webstructural.com/beam-deflection-formulas.html) give the deflection for 19 standard cases, and the [beam calculator](https://webstructural.com/beam-calculator.html) draws the deflection for any beam, so you can check each step above.
- The [shear and moment diagram calculator](https://webstructural.com/beam-calculator.html) handles several loads at once and continuous beams.
- The [beam designer](https://webstructural.com/beam-designer.html) runs the deflection, bending and shear checks together and suggests shapes that pass.

## Frequently asked questions

### What is the deflection formula for a simply supported beam?

5wL⁴/(384EI) for a uniform load and PL³/(48EI) for a point load at midspan. Add them when both act.

### What does L/360 mean?

The beam may deflect no more than its span divided by 360. For a 20 ft (240 in) span, that's 0.67 in.

### Do I check deflection with factored loads?

No. Deflection is a serviceability check, so it uses the loads as they are, without load factors.

More worked examples: [browse all structural design tutorials](https://webstructural.com/structural-learning-hub.html).